washer dryer

MetNurs

The MetNurs washer-dryer combines washing and drying functions in a single appliance, ideal for cleaning and drying your clothes quickly and conveniently.

Italiano Manuale d'uso Aspiro-vapore SteamForce V8 PDF · 158,0 KB · 2 pages · Italiano

Wiring diagrams, CAD drawings, exploded parts, and technical data sheets.

Sostituzione del panno JPG · 43,2 KB · 1 page
Pulizia aspirazione JPG · 36,5 KB · 1 page Pulizia da oggetto che blocca l'aspirazione
Filtro aria JPG · 37,7 KB · 1 page Riparazione del filtro dell'aria
Snodo blocco JPG · 35,8 KB · 1 page Sostituzione molla dello sblocco
Italiano Manuale tecnico PDF · 162,6 KB · 4 pages · Italiano
Italiano Schema elettrico PDF · 134,0 KB · 1 page · Italiano

Electrical

Suction power
1,400 W
Boiler power
1,600 W
Power supply
230 V~ 50 Hz
Cable length
6 m

Performance

Steam pressure
4.5 bar

Capacity

Boiler capacity
1.6 liters

The spare parts for this QR. The code is the one to dictate when you order.

5214256 Replacement floor cloth
654987 Accessory set, window cleaner, floor, bathroom
6532145 Motor filter
234424 O-ring kit for hoses and accessories

Authorized service centers: here you order spare parts and book a repair.

ScanEron Assistenza Via Ghianda, 27 · 36060 Romano D'Ezzelino
Spare parts Repairs Warranty

Lun-Ven 8:00 12:00

How do you start the SteamForce V8 vacuum cleaner?
1. Fill the boiler with cold water without exceeding the maximum level. 2. Tighten the safety cap well. 3. Turn on the boiler switch and wait for the ready light. 4. Attach the accessory and unlock the safety button on the handle.
What does the red water light mean?
The red light indicates that the boiler is empty. Turn off the device, wait for it to cool down, and refill.
How do you clean the HEPA filter?
Wash the HEPA filter every month and let it dry for 24 hours.
How often should I maintain the boiler?
Rinse the boiler every 3 months to remove limescale.
What should I do if there is no steam?
Wait for the light to be ready or clean the nozzle if it is clogged.
What should I do if the suction is weak?
Check and clean the filter and ducts, as they may be dirty or blocked.
How do you empty the container after use?
Empty the container and rinse the filter after each use.
What should I do if there are steam leaks from the cap?
Replace the safety cap gasket, as it may be worn out.